Series M6B 90-Second Processor
This processor has quickly become the Processor of Choice for
General Radiography and Mammography. Built-in electronics, combined with
standard upgrades, make it an excellent value as well as a reliable part of
your radiology department.
Plumbing
A brand-new molded tank is used to begin the internal refurbishing process.
The heat exchangers are sealed in with new seals and compression nuts and
new tubing are used to plumb the machine throughout. A new March
recirculation pump is installed, as is a Gorman-Rupp bellows replenishment
pump. To ensure accurate replenishment rates in the plumbing system, a new
incoming water solenoid valve is used to facilitate water conservation and a
new developer cooling solenoid is also installed to maintain proper
development temperatures.
Temperature Sensing
The M6B has two electronically-controlled temperature sensing systems—the
dryer and developer temperature control. The dryer is maintained through the
use of new thoroughly tested thermistor, new dryer temperature potentiometer
and reconditioned dryer heaters. The system is protected with an
overtemperature safety thermostat and a new blower motor is used to
recirculate the tempered air through the system. The blower assembly (which
is rebuilt completely with new bearings, main shaft, squirrel cage and
machined pulleys) completes the dryer temperature control section. The
developer temperature control system is maintained through the use of a new
thermistor, new or used developer heater assembly and is protected by an
overtemperature device for safety. The sensing circuit on the PCB100 board
monitors and controls all activities. The recirculation pump circulates the
developer consistently throughout the system, to ensure uniformity in
temperature. Finally, the developer is constantly being filtered through the
new filter canister assembly and a new LED display of the developer
temperature completes the system.
External Features
All units are finished with new internal plastics and new panel sets. The
new "greige" color finish is both an aesthetic and eye-pleasing finish.
Electrical Requirements
This unit requires 240 volts. 30amp. Other electrical configurations can be
accommodated upon request.
Water Requirements
Requires cold water only. Other specifications available upon request.
Controlled Testing Environment
TI-BA refurbished processors are tested for a minimum of 36 hours to ensure
trouble-free operation prior to shipment to customer locations. All
adjustments and calibrations are performed during this period.
Available Options
| Drip Tray | Air Exhaust Kit |