Designed for facilities receiving unit
doses including PET.
|
All functions microprocessor controlled
|
|
Ultra-fast response
|
|
Automatic range selection Ranges up to 9.999 curies of
Tc-99m or 2.5 curies of F-18
|
|
Pre-programmed for the most commonly used radionuclides
|
|
Display in Curies or Becquerels
|
|
Automatic background subtraction and zeroing at the touch
of a button
|
|
Remote ionization chamber with .25" (.64 cm) lead
shielding and 10-foot cable
|
|
Self-diagnostic software
|
|
Daily constancy isotope keys
|
|
Electronic power supply (no battery in chamber)
|
|
Industry exclusive two-year warranty
|
|
ETL to UL 3101-1 and cETL to CAN/CSA C22.2 No. 1010.1-M92
|
The Atomlab 100 provides fast, accurate
radionuclide activity measurements with performance that easily surpasses
the most stringent regulatory requirements.
The unit is simple to operate. There are 13
isotope selection keys, ten are pre-programmed for the most commonly used
radionuclides, and three are user defined. Any key can be reprogrammed by
the user for a desired isotope.
Activity is displayed on a LED readout in
either Curie or Becquerel units. Background correction and zero adjustment
are performed at the touch of a button. Range selection is automatic.
Activity measurements are performed by a
microprocessor controlled electrometer located within the detector assembly
of the ionization chamber. The chamber is shielded with .25" (.64 cm) lead.
It can be located up to ten feet away from the display unit. Chamber bias is
generated within the display unit by an electronic high voltage supply,
eliminating the need for expensive battery changes.
An optional RS-232 port enables the Atomlab
100 Dose Calibrator to communicate with most commercially available nuclear
medicine management systems.
An industry exclusive two-year warranty is
standard.
|
Isotope Selection Keys: Ten pre-programmed — Tc-99m,
Tl-201, Mo-99; I-123; Xe-133, Ga-67, In-111, I-131, Cs-137, and Co-57;
Three additional keys for user-defined isotopes.
|
|
Activity Range: 0.01 µCi to 9999 mCi (.001 mBq to 399.9
GBq) of Tc-99m
|
|
Energy Range: 25 keV to 3 MeV photons
|
|
Response Time: One second for doses greater than 2 mCi;
Three seconds between 200 µCi and 2 mCi; 3-30 seconds below 200 µCi
|
|
Detector Linearity: ±1% or 0.2 µCi, whichever is greater
|
|
Electrometer Linearity: ±1% or 0.2 µCi, whichever is
greater
|
|
Electrometer Accuracy: ±1% or 0.2 µCi, whichever is
greater
|
|
Overall Accuracy:±3% or 0.3 µCi, whichever is greater.
Overall accuracy is affected by such factors as the accuracy of the
specific source calibration, geometric variations due to sample volume
or configuration, detector linearity, electrometer accuracy and readout
accuracy
|
|
Repeatability: ±0.3% above 1 mCi short term (24 hr); 1%
long term (1 yr); exclusive of background
|
|
Digital Calibration Dial: Four-digit LED dial display
with increment/decrement keys to change the value. Range is from 0.1 to
999
|
|
Detector: Well-type pressurized ionization chamber, with
Argon fill gas Well opening 2.75" (7 cm), well depth is 10.5" (26.7 cm)
|
|
Detector Shielding:.25" (6.3 mm) lead on all sides except
top well opening. Supplementary shielding available.
|
|
Chamber Bias: 340 volt electronic power supply
|
|
Environmental Operating Conditions: Temperature: 0-40° C
|
|
Humidity: 0-90% rh, non-condensing
|
|
Power Requirements: 100 to 120 VAC @ 1/2A; 200 to 240 VAC
@ 1/4A
|
|
Line Frequency: 50/60 Hz; Detachable line cord; Built-in
EMI filter and transient suppression
|
|
Detector and Interface Cables:10' (304.8 cm) long, six
conductor cables (two carry power, one is chassis ground, three carry
serial data for digital I/O); Ends terminated with AMP Mate-n-Lock
connectors, white with hooded strain relief
|
|
Display Unit:
Dimensions: 12" w x 14.3" depth x 3.75" h (30.5 x 36.3 x 9.5 cm)
Weight: 6 lb (2.7 kg)
|
|
Detector Unit:
Dimensions: 7.5" w x 7.5" depth x 16.25" h (19 x 19 x 41.3 cm)
Well I. D.: 2.75" dia x 10.5" h (7 x 26.7 cm)
Well I. D. with Liner: 2.5" dia x 10.25" h (6.35 x 26 cm)
Lead Shielding: .25" thick (.63 cm)
Weight: 35 lb (16 kg)
|
|
Approvals: ETL to UL 3101-1 and cETL to CAN/CSA C22.2 No.
1010.1-M9
|
|
|
086-250 |
Dose
Calibrator, Atomlab 100
Includes Vial/Syringe Dipper and Well Insert |
|
|
086-251 |
Dose
Calibrator, Atomlab 100, RS-232 port
Includes Vial/Syringe Dipper and Well Insert |
|
|
Optional:
|
|
086-257 |
Voltage
Configuration, 230V
For 086-250. |
|
|
086-258 |
Voltage
Configuration, 230V
For 086-251. |
|
Must be purchased with Atomlab
Dose Calibrator. |
|
Related:
|
|
086-301 |
Dose
Calibrator Shielding Rings,
Interlocking, 2" lead
For additional protection from high energy activity. |
|
|
086-423 |
Moly
Shield, Vial, .28" lead |
|
|
086-435 |
Moly
Shield, Syringe, .28" lead |
|
|
|
Replacement:
|
|
086-242 |
Vial/Syringe Dipper |
|
|
|
|
|
|